Cuff placement on nerve
This section provides an overview of how the cuff is placed on the
nerve. The compute_cuff_shift()
method within Runner (src/runner.py
)
determines the cuff’s rotation around the nerve and translation in the
(x,y)-plane. The pipeline imports the coordinates of the traces for the
nerve tissue boundaries saved in
samples/<sample_index>/slides/0/0/sectionwise2d/
which are, by
convention, shifted such that the centroid of the nerve is at the origin
(0,0) (i.e., nerve centroid from best-fit ellipse if nerve trace (n.tif
)
is provided, inner or outer best-fit ellipse centroid for monofascicular
nerves without nerve trace). Importantly, the nerve sample cross section
is never moved from or rotated around the origin in COMSOL. By
maintaining consistent nerve location across all Model’s for a
Sample, the coordinates in fibersets/
are correct for any
orientation of a cuff on the nerve.
ASCENT has different CuffShiftModes
(i.e., “cuff_shift”
parameter in
Model) that control the translation of the cuff (i.e., “shift”
JSON Object in Model) and default rotation around the nerve (i.e.,
“pos_ang”
in Model). Runner’s compute_cuff_shift()
method is
easily expandable for users to add their own CuffShiftModes
to control
cuff placement on the nerve.
The rotation and translation of the cuff are populated
automatically by the compute_cuff_shift()
method based on sample morphology, parameterization of the “preset” cuff, and the CuffShiftMode
, and are defined in the “cuff” JSON
Object (“shift” and “rotate”) in Model.
For “naïve” CuffShiftModes
(i.e.,
“NAIVE_ROTATION_MIN_CIRCLE_BOUNDARY”, “NAIVE_ROTATION_TRACE_BOUNDARY”
) the cuff is placed on the nerve
with rotation according to the parameters used to instantiate the cuff
from part primitives (S16, S17, and S18 Text). If the user would like to rotate the cuff from
beyond this position, they may set the “add_ang”
parameter in
Model (S8 Text). For naïve CuffShiftModes
, the cuff is shifted along the
vector from (0,0) in the direction of the “angle_to_contacts_deg”
parameter in the “preset” JSON file.
“NAIVE_ROTATION_MIN_CIRCLE_BOUNDARY”
CuffShiftMode
moves the cuff
toward the nerve until the nerve’s minimum radius enclosing circle is
within the distance of the “thk_medium_gap_internal”
parameter for
the cuff. “NAIVE_ROTATION_TRACE_BOUNDARY”
CuffShiftMode
moves the
cuff toward the nerve until the nerve’s outermost Trace (i.e., for
monofascicular nerve an inner or outer, and same result as
“NAIVE_ROTATION_MIN_CIRCLE_BOUNDARY”
for nerve’s with epineurium)
is within the distance of the “thk_medium_gap_internal”
parameter for
the cuff. Note: orientation masks (a.tif
) are ignored when using these modes.
For “automatic” CuffShiftModes
(i.e.,
“AUTO_ROTATION_MIN_CIRCLE_BOUNDARY”, “AUTO_ROTATION_TRACE_BOUNDARY”
) the cuff is rotated around the
nerve based on the size and position of the nerve’s fascicle(s) before
the cuff is moved toward the nerve sample (Figure A). The point at
the intersection of the vector from (0,0) in the direction of the
“angle_to_contacts_deg”
parameter in the “preset” JSON file with
the cuff (i.e., cuff’s “center” in following text) is rotated to meet a specific location of the nerve/monofascicle’s
surface. Specifically, the center of the cuff is rotated around the
nerve to make (0,0), the center of the cuff, and Sample’s
“fascicle_centroid”
(computed with Slide’s fascicle_centroid()
method, which calculates the area and centroid of each inner and then
averages the inners’ centroids weighted by each inner’s area) colinear.
If the user would like to rotate the cuff from beyond this position, they may set the
“add_ang”
parameter in Model (S8 Text). The user may override the
default “AUTO” rotation of the cuff on the nerve by adding an
orientation mask (a.tif
) to align a certain surface of the nerve sample
with the cuff’s center (S11 Text). This behavior depends on the
cuff’s "fixed_point"
parameter (S17 text) The “AUTO_ROTATION_MIN_CIRCLE_BOUNDARY”
CuffShiftMode
moves the cuff toward the nerve until the nerve’s minimum
radius enclosing circle is within the distance of the
“thk_medium_gap_internal”
parameter for the cuff.
“AUTO_ROTATION_TRACE_BOUNDARY”
CuffShiftMode
moves the cuff toward
the nerve until the nerve’s outermost Trace (i.e., for monofascicular
nerve an inner or outer, and same result as
“AUTO_ROTATION_MIN_CIRCLE_BOUNDARY”
for nerve’s with epineurium)
is within the distance of the “thk_medium_gap_internal”
parameter for
the cuff.
Figure A. Demonstration of cuff placement on a multifascicular nerve (top) and a monofascicular nerve without epineurium (bottom) with the same “preset” cuff (Purdue.json) for three different cuff rotations using the “AUTO_ROTATION_TRACE_BOUNDARY” CuffShiftMode. The cuff rotations are different in the top and bottom rows since the point on the surface of the nerve sample closest to the most endoneurium is unique to each sample (black arrows). Additional angles of rotation were applied to the cuff directly using the “add_ang” parameter in the Model’s “cuff” JSON Object (red arrows).
The default z-position of each part along the nerve is defined in the “preset” cuff JSON file by the expression assigned to the part instance’s “Center” parameter (referenced to z = 0 at one end of the model’s proximal cylindrical domain). However, if the user would like to move the entire “preset” cuff along the length of the nerve, in the “cuff” JSON Object within Model, the user may change the “z” parameter.
Since some cuffs can open in response to a nerve diameter larger
than the manufactured cuff’s inner diameter, they maybe be parameterized
as a function of “R_in”
. In this case, in the “preset” cuff JSON, the
“expandable” Boolean parameter is true. If the cuff is “expandable”
and the minimum enclosing diameter of the sample is larger than the
cuff, the program will modify the angle for the center of the cuff to
preserve the length of materials. If the cuff is not expandable and the
sum of the minimum enclosing circle radius of the sample and
“thk_medium_gap_internal”
are larger than the inner radius of the
cuff, an error is thrown as the cuff cannot accommodate the sample
morphology.
The inner radius of the cuff is defined within the list of “params” in
each “preset” cuff configuration file as “R_in”
, and a JSON Object
called “offset” contains a parameterized definition of any additional
buffer required within the inner radius of the cuff (e.g., exposed wire
contacts as in the Purdue.json
cuff “preset”). Each key in the “offset”
JSON Object must match a parameter value defined in the “params” list of
the cuff configuration file. For each key in “offset”, the value is the
multiplicative coefficient for the parameter key to include in a sum of
all key-value products. For example, in Purdue.json
:
"offset": {
"sep_wire_P": 1, // separation between outer boundary of wire contact and internal
// surface of insulator
"r_wire_P": 2 // radius of the wire contact’s gauge
}
This JSON Object in Purdue.json
will instruct the system to maintain
added separation between the internal surface of the cuff and the nerve
of: